The AC2500 is a dual active output amplifier with 2 x 43 dB operational gain. It offers high output level (111.5 dBμV, 112 channels) and supports 1.2 GHz/204 MHz bandwidth.

The AC2500 amplifier is equipped with the latest technology and delivers incredible performance, flexibility and cost-effectiveness. This amplifier can be used as high gain distribution amplifier, but also as a lower gain trunk amplifier with bridger output. The AC2500 also complies with the DOCSIS 3.1 standard, an important feature designed to meet future service requirements.

Features at a glance:

  • 1.2 GHz bandwidth
  • Forward amplifiers use GaN HEMT and GaAs pHEMT technology
  • GaAs push-pull return amplifier on the motherboard
  • Temperature compensated forward and return path
  • Flexible 862/1006/1218 MHz interstage slope pivot point selection
  • Excellent ESD and surge protection
  • Remote power supply with PFC
  • Fixed station memory for electrical identification
  • Optional AC6188 temperature compensating MLSC unit with RIS
  • Optional AC6158 agile pilot ALSC unit with RIS

Product Specifications

Downstream signal path (values with diplex filters)
Frequency range
85…1218 MHz
Return loss
20 dB
Operational distribution gain
2 x 43 dB
Maximum distribution gain
2 x 47 dB
Operational trunk gain
35 dB
Maximum trunk gain
41 dB
Input attenuator control range
20 dB
Input equaliser control range
25 dB
Interstage nominal slope (distr./trunk)
13 dB/7 dB
Pivot point frequency
862 MHz/1006 MHz/1218 MHz
Interstage slope control
±4 dB
Interstage gain control
±4 dB
Flatness
±0.4 dB
Group delay
2 ns
Test point
-20 dB
Noise figure
< 5.7 dB
Umax (112 x QAM channels) @ 1 GHz (distr./trunk)
111.5 dBµV/109.5 dBuV
Umax(138 x QAM channels) @ 1.2 GHz (distr./trunk)
108.5 dBµV/107.0 dBµV
CTB 41 channels (distr./trunk)
117.5 dBµV/115.5 dBµV
CSO 41 channels (distr./trunk)
120.0 dBµV/118.0 dBµV
XMOD 41 channels (distr./trunk)
114.5 dBµV/112.0 dBµV
CTB mixed raster (distr./trunk)
79 dB/79 dB
CSO mixed raster (distr./trunk)
73 dB/73 dB
Upstream signal path (values with diplex filters)
Frequency range
5…65/85/204 MHz
Return loss
18 dB
Gain
2 x 28 dB
Ingress switching
0/-6/< -45 dB
Output attenuator control range
0…- 15 dB
High/low gain mode selection
2 x 28 dB/2 x 16 dB
Nominal slope (65/204 MHz)
0/3 dB
Equaliser control range
0…15 dB
Flatness
±0.5 dB
Noise figure, f<65 MHz
< 7.0 dB
Noise figure, f<204 MHz
< 8.5 dB
General
Power consumption (65 & 90/230 VAC)
38/40 W
Supply voltage
27…65/40…90/205…255 VAC
Maximum current feed through
7.0 A/port
Hum modulation
70 dB
Resistance for remote current
25 mΩ/port
Input/Output connectors
PG11 thread, other types available
Test point connectors
F female
Dimensions (h x w x d)
245 mm x 255 mm x 107 mm
Weight
3.9 kg
Operating temperature
-40…+60 °C
Class of enclosure
IP67
EMC
EN50083-2
ESD
4 kV
Surge
6 kV (EN 60728-3)
Image illustrates the Accessories link.

Accessories

Teleste offers a variety of accessories including both active and passive modules and power solutions. The accessories are designed and tested for Teleste broadband equipment. Find the products that suit you and get more of your network.

Image illustrates the Support link.

Support

Teleste´s experts are available for providing professional support. Find out how we can be at your service.